DSM / DRECAM / SCM | Laboratoire Interdisciplinaire sur l'Organisation Nanométrique et Supramoléculaire |
Device Server |
|
|||
( Read the most recent complete data point from counter A Gpib command QA if data is not ready returns -1 ) |
|||
( Read the most recent complete data point from counter A Gpib command QA if data is not ready returns -1 ) |
|||
( Counting Mode CM: 0- A,B for T preset 1- A-B for T preset 2-A+B for T preset 3- A for B preset ) |
|||
( Gate trigger Slope: 0->RISE 1->FALL Gpib command : TS ) |
|||
( Gate trigger level resolution is .001 Gpib command : TL ) |
|||
( number of period NP in a scan ) |
|||
( Gpib command : NN ) |
|||
( Scan end mode Gpib command : NE ) |
|||
( dwell time 2e-3 <= x <= 6e1 if x=0 dwell is set to EXTERNAL Gpib command : DT ) |
|||
( set and read the D/A output source 0=A 1=B 2=A-B 3=A+B Gpib command : AS ) |
|||
( set the D/A output scale : 0 log(1V/decade) 1=987###### 2=#876##### ... Gpib command : AM ) |
|||
( set and read the count display mode 0=CONTINUOUS 1=HOLD Gpib command : SD ) |
|||
( Mean values of events in buffers = count/number_of_period ) |
|||
( Standard deviation from BufferA - BufferB ) |
|
|||
( dsicriminator slopes for A,B,T 0=RISE 1=FALL Gpib command : DS ) |
|||
( set and read the counter inputs : counter inputs CI - 0= 10Mhz - 1= INPUT 1 - 2=INPUT 2 - 3= TRIG ) |
|||
( set and read the counters presets CP for B ot T : n is a value from 1 ro 9E11 ) |
|||
( set and read the D/A output mode for PORT1 and PORT2 0=FIXED 1=SCAN Gpib command : PM ) |
|||
( set and read the scan step for PORT1 and PORT2 -0.500<= V <= 0.500 Gpib command : PY ) |
|||
( set and read the output level for PORT1 and PORT2 -10.000<= V <= 10.000 Gpib command : PL ) |
|||
( Gpib command : PZ ) |
|||
( Gates modes for A,B 0=CW 1=FIXED 2=SCAN Gpib command : GM ) |
|||
( Gates delay scan steps for A,B 0<= t <= 99.92e-3 Gpib command : GY ) |
|||
( Gates delay position during scan for A,B 0<= t <= 999.2e-3 Gpib command : GZ ) |
|||
( Gates widths for A,B 0.005e6<= t <= 999.2e-3 Gpib command : GW ) |
|||
( Gates modes for A,B or T 0=FIXED 1=SCAN Gpib command : DM ) |
|||
( Gates delay scan steps for A,B or T -0.200<= V <= 0.0200 Gpib command : DY ) |
|||
( Gates delay scan steps for A,B or T -0.3000<= V <= 0.3000 Gpib command : DL ) |
|||
( read the discriminators levels during a scan for A (0) , B (1), T(2) gpib command : DL i{ ,v} -0.3000 <= v<=0.3000 ) |
|||
CEA / DSM / DRECAM / SCM / LIONS
Olivier Taché : olivier.tachecea.fr